CCTLY - LATEX FLAT WALL PAINT, 350-SERIES (ALL COLORS)

  • MSDS: CCTLY
  • Manufacturer: KELLY MOORE PAINT CO INC
  • Product Name: LATEX FLAT WALL PAINT, 350-SERIES (ALL COLORS)
  • National Stock Number: 8010-00N075104
Product Identification

Product ID:LATEX FLAT WALL PAINT, 350-SERIES (ALL COLORS)
MSDS Date:09/20/1994
FSC:8010
NIIN:00N075104
MSDS Number: CCTLY

Responsible Party
KELLY-MOORE PAINT CO INC
1015 COMMERCIAL ST
SAN CARLOS, CA 94070
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 415-592-8337

Preparer: JULIAN SCHAFER

Cage: 0Y837

Contractor
KELLY-MOORE PAINT CO INC
SAN CARLOS, CA 94070 US

Telephone: 650-592-8337

Cage: 0Y837

Ingredients

MINERAL SILICATES

CAS: 1332-58-7

OSHA PEL N/K

ACGIH TLV: N/K


SILICON DIOXIDE

CAS: 14808-57-0

OSHA PEL N/K

ACGIH TLV: N/K


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST


SILICA, CRYSTALLINE - QUARTZ; (CRYSTALLINE SILICA)

CAS: 14808-60-7

RTECS: VV7330000

Fraction By Weight: TRACE

OSHA PEL SEE TABLE Z-3

ACGIH TLV: 0.1 MG/M3 RDUST


4-ISOTHIAZOLIN-3-ONE, 5-CHLORO-2-METHYL-; (PAINT

CAS: 26172-55-4

RTECS: NX8156850

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:DIZZINESS, HEADACHE, NAUSEA,
CONFUSION, IRRITATION TO UPPER RESPIRATORY TRACT, UNCONSCIOUSNESS,
SKIN AND EYE IRRITATION. THIS PRODUCT CONTAINS PIGMENTS WHICH ARE
NOT HAZARDOUS IN WET PAINT, BUT MAY REACH HAZARDOUS LEVELS IN
DUSTS GENERATED FROM SANDING OR GRINDING OF DRIED PAINT. LIKE (EFTS
OF OVEREXP)
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-QUARTZ:IARC
MONOGRAPHS, SUPP, VOL 7, PG 341, 1987:GRP 2A. NTP 7TH ANNUAL RPT ON
CARCINS, (SUPP DATA)
Effects of Overexposure:HLTH HAZ:MOST NATURALLY OCCURING MINERALS,
PIGMENTS CNTN TRACES OF CRYSTALLINE SILICA. IARC HAS DETERMINED
THAT THERE IS LTD EVID FOR CARCIN OF CRYSTALLINE SILICA TO HUMANS,
W/RISK DEPENDING ON DURATI ON & LEVEL OF EXPOS. A PAINT
PRESERVATIVE HAS BEEN ADDED TO CONTROL MICRO-ORGANISMS AT LEVEL
THAT IS NOT CONSIDERED HAZ.
Medical Cond Aggravated by Exposure:NONE KNOWN. SEE YOUR MD FOR
SPECIFIC MEDICAL OPINION REGARDING YOUR CONDITION.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. RESTORE BREATHING. CONSULT MD.
EYES:FLUSH W/LARGE VOLUMES OF WATER FOR AT LEAST 15 MINUTES. GET
MEDICAL ATTENTION. SKIN:WIPE OFF W/RAG. WASH THOROUGHLY W/SOAP &
WATER. INGES T:CONSULT HOSPITAL EMERGENCY ROOM OR POISON CONTROL
CENTER IMMEDIATELY.

Fire Fighting

Flash Point:NONE
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE (DUE TO THE
BUILD-UP OF STEAM PRESSURE) WHEN EXPOSED TO EXTREME HEAT.

Accidental Release

Spill Release Procedures:VENTILATE AREA TO PREVENT BUILD-UP OF VAPORS.
FOR SMALL SPILLS, SOAK UP W/ABSORBENT. FOR LARGER SPILLS, DIKE AREA
W/ABSORBENT MATERIAL & SCOOP UP LIQUIDS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE UPRIGHT IN SEALED CONTAINERS
AWAY FROM HEAT & FLAME.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:USE NIOSH APPRVD PARTICLE MASK (TC-21C) TO AVOID
BRTHG SPRAY MIST/SANDING DUST IF LOC VENT IS ADEQ TO KEEP VAP CONCS
W/IN ACCEPT (TLV) LIMS. IF LOC VENT IS NOT SUFFICIENT/WHERE EXPOS
LIMS ARE EXCEEDED , WEAR SUITABLE, PROPERLY FITTED(SUPDAT)
Ventilation:LOCAL CROSS-VENT OR MECHANICAL EXHAUST SUFFICIENT TO KEEP
ALL HAZARDOUS VAPOR CONCENTRATIONS BELOW PRESCRIBED LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:REMOVE & WASH CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
EXPLAN OF CARCIN:1994:ANTICIPATED TO BE CARCINOGEN. RESP PROT:NIOSH
APPROVED RESPIRATOR (TC-23C OR BETTER) FOR ORGANIC VAPORS W/DUST
FILTER AS NEEDED.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Vapor Density:LTR/AIR
Spec Gravity:1.32-1.44
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:68-72

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products:MAY PRODUCE HAZARDOUS FUMES WHEN
HEATED TO DECOMPOSITION AS IN WELDING.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . DISCARD IN LANDFILL IN SEALED METAL CONTAINERS AWAY
FROM HEAT & FLAME & I/A/W LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.